Tender Description

Supply, Installation, Testing And Commissioning Of Hvac Work At Taloja Ffs Packing Section On Turnkey Basis

Premium JV Support
Only 2 days left to bid
JV for this Tender

Faster paperwork • Compliant docs • Right partners

Compact JV pack: MoU + compliance + roles + timelines — delivered against your bid deadline.

Custom JV Agreement & MoU
PQC & compliance paperwork
Workshare & risk allocation
Fast turnaround
We align delivery to your deadline (11-Feb-2026).
JV Essentials Checklist
  • Lead & Partner credentials (experience, turnover)
  • Profit share / Workshare matrix
  • Board/Partner resolutions & authorizations
  • JV Agreement / MoU (stamp & notarization)
  • Bid-specific annexures & declarations
Compliant Docs
Fast Turnaround
Dedicated Expert
Items Total Items : 93 | Total Qty : 327
List of items to be supplied
Sr. NoItem DescriptionQtyUnit
1 PLATE HEAT EXCHANGER 1W +1SSupply installation testing and commissioning of PLATE TYPE Water to Water HEAT EXCHANGER with Openable Insulation Jacketing of 75 MM thick TF Quality EP as per Specifications 2.00 Nos.
2 Chemical flushing and passivation :Supply, erection and testing of chemical flushing, Passivation and First charge of chemical in complete pipe network to maintain Nitrite level in chilled water system 300-350 PPM complete with chemicals and necessary accessories. 1.00 Lot
3 Automatic chemical dosing system: Supply, installation, testing and commissioning of Automated chemical dosing system complete with positive displacement dosing (metering) pump, control panel, sensor / monitoring sensors, drum of 25 ltr with chemical. 1.00 Nos.
4 Manual chemical dosing pot: Supply, installation, testing and commissioning of manual chemical dosing pot complete all accessories such as valves, funnel, pot of minimum 2 ltr etc. 1.00 Nos.
5 TERTIARY CHILLED WATER VERTICAL INLINE PUMPS ON PHE LOAD HOT SIDE with VFD VSPS SYSTEM WITH DPT AND CONTROL CABLIN. Supply installation testing and commissioning of Vertical Inline type pumps. The pumps shall have bronze impeller SS 316 Gland Plate, shaft, wear rings, seals, bearings. The pump shall have flexible type couplings. Motor shall be TEFC IP55 Sq Cage IE 2 type suitable for 415 plus 10percent volts 50 Hz 3phase AC power supply. refer technical specifications.The pump shall be mounted on common base frame. The maximum permissible sound level of the pump shall not exceed 85dbA measured at 1m from pump surface. The pump shall be supplied with necessary vibration isolators with floating frame. The motors of pumps shall be suitable for operation on Adjustable frequency drive. VFD shall have provision to receive 4to20mA0to10 V signal from CPO Chiller Plant optimizer. The motor selected shall be energy efficient having efficiency IE3 at full load ranging between 91.5percent to 94percent in accordance with motor rating as per specification. The quoted price shall include cost of thermal insulation and cladding for chilled water pumps. Pumps with performance characteristics as given below.Each pump shall be provided with concrete inertia base with weight of minimum two times than that of the pump.Inertia base shall be encased concrete with IS 2062 sheet steel as barriers.VFDs Ambient temp 50 Deg without deration 100kA SC rating with built in harmonic reduction technology to limit THDiless than 5percent at 100percent load and 75percent load with input PFgreater0.99 even at 50percent load as per IEC 61800 2Valid third party test report should be available to suffice this claim own test report by manufacturer shall not be considered.The drive shall utilize efficient technology throughout the entire drive manufacturers power and voltage range to reduce the current harmonics at equipment level within the drive itself or individual active harmonic filters connected in parallel can be used in combination with an AC drive. VFD shall have a provision to automatically stop the PWM switching operation and switch to operation with a direct commercial power supply connection when output frequency matches with power supply frequency. Criteria for change over should be definable via parameters. Also VFD should be capable of returning to PWM mode when required Water Qty165 USGPM Head 15 Mtrs Impeller SS Speed NOT MORE THAN 1450 RPM Seal Mechanical Pumps must withstand minimum pressure of PN25 Minimum Efficinecy not less than 75percent NOTE VFD panel for all the above pumps shall be common with minmum IP 54 rating. 2.00 Nos.
View more BOQ items
Key Dates
Tender timeline
Publish Date Wed 21st January, 2026
Bid Submission Deadline Wed 11th February, 2026
Bid Opening Refer Documents
Documents
Official tender documents
Document NameAction
Tender Notice
FAQs

Sign up, download the bid documents, and submit as per the Key Dates. Need help? Talk to an expert.

Yes—JV MoU, compliance, share matrix, and end-to-end guidance. Start here.

We can help with PQC, technical compliance, and pricing strategies. Enquire now.
Have questions about TKID 18612887?
WhatsApp